General Purpose Door Systems Disclosure

Product Line: General Purpose Door Systems
Version: v1.0.0
Last Updated: 2026-03-08
Classification: Class 2 Designated Building Product

Product System Details

Product Name: RCD General Purpose Door Systems

Unique Product Identifiers: RCD-GP-SC (Solid Core), RCD-GP-CS (Cavity Slider), RCD-GP-BF (Bi-Fold), RCD-GP-FS (Face Slider)

Intended Use: General purpose internal and external door assemblies for commercial, education, healthcare, and multi-residential buildings. Includes solid core hinged doors, cavity sliders, bi-fold doors, and face sliders.

Door Types Available:

  • Solid Core Hinged Doors (timber frame or steel frame)
  • Cavity Sliders
  • Bi-Fold Doors
  • Face Sliders
These are general purpose door systems. They are not fire rated and not acoustic rated. Do not specify where fire resistance or STC/Rw performance is required. See the dedicated BPIR disclosure pages for fire, acoustic, or specialist door systems.

Manufacturer Details

Field Content
Legal Name Restruct Commercial Doors Ltd
Trading Name Restruct Commercial Doors
NZBN 9429051277055
Address 18 Waimakariri Park Drive, Kainga, Christchurch, Canterbury, New Zealand, 8083
Phone +64 21 860 326
Email admin@restructcommercialdoors.co.nz
Website restructcommercialdoors.co.nz

Standards & Building Code Compliance

Standard/Code Description Status
NZBC Clause D1 Access routes — door operation, clearances, and accessibility Compliant
NZBC Clause B2 Durability Compliant
NZBC Clause F2 Hazardous building materials Compliant
NZBC Clause E2 External moisture (external doors only) Compliant
NZS 4121:2001 Design for access and mobility — buildings and associated facilities Compliant
AS/NZS 2688 Timber doors — standard and performance requirements Compliant

Product Specifications

Specification Details
Door Types Solid Core Hinged (timber or steel frame), Cavity Slider, Bi-Fold, Face Slider
Door Core Construction Solid core construction for commercial durability and stability
Door Skin/Facing High-Pressure Laminate (HPL), Veneer, Metal Skin, Decorative Timber Moulding, Autex, or Paint Grade Finish
Frame Material — Steel 1 Piece 1.6mm Electro Galvanized Steel, Powder Coated Finish
Frame Material — Timber 30mm minimum Hardwood Timber Jamb
Standard Sizes — Width 710mm, 810mm, 860mm, 910mm, 960mm, 1020mm
Standard Sizes — Heights 1980mm, 2020mm, 2100mm, 2200mm, 2400mm
Door Thickness 40mm (standard), 45mm (heavy duty)
Vision Panel Optional glazed panel as specified per project requirements
Hardware 304 Stainless Steel Ball Bearing Hinges, Optional Hardware Installation
Installation Requirements Must be installed by competent personnel per manufacturer's installation instructions
Warranty 5 years (Internal Doors) on materials and workmanship (conditions apply)

Hardware Components

Note: Hardware is supplied and installed per project specifications. Contact Restruct Commercial Doors for compatible hardware recommendations.
  • Hinges: 304 Stainless Steel Ball Bearing Hinges, minimum 3 per door. Must support door weight and maintain correct leaf-to-frame alignment.
  • Handles/Lever Sets: As specified per project requirements. Lever handles on both sides (exit hardware where required).
  • Door Closers: Where required per project specification. Adjustable closing speed and latch action.
  • Locks: As specified per project requirements. Tubular latch or mortice lock with furniture.
  • Cavity Slider Hardware: Heavy duty commercial grade tracks and guides. Track system must support door weight with smooth, reliable operation.
  • Bi-Fold Hardware: Commercial grade pivot and track systems. Top and bottom pivot sets as required.
  • Face Slider Hardware: Commercial grade face-mounted track and roller systems. Soft-close mechanisms where specified.

Installation Requirements

Competent Installation Required

General purpose doors must be installed by competent personnel in accordance with manufacturer specifications. We can provide installation with our experienced installation team.

Installation Standards

  • Installation must comply with manufacturer's installation instructions and drawings.
  • Door frames must be plumb, level, and securely fixed to the wall structure.
  • Clearances between door leaf and frame must be within manufacturer's specified tolerances.
  • All gaps between frame and structural opening must be filled and finished per manufacturer instructions.
  • Hardware must be installed per manufacturer specifications.
  • Door must close fully and latch from any open position.

Door Type Specific Requirements

  • Solid Core Hinged: Frame must be securely fixed to wall structure. Hinges must be correctly aligned for smooth operation.
  • Cavity Sliders: Wall cavity must have adequate depth for the door leaf and track system. Cavity framing must be rigid and plumb.
  • Bi-Fold Doors: Top and bottom tracks must be level and securely fixed. Pivot points correctly aligned.
  • Face Sliders: Track must be securely fixed to wall structure at the correct height. Adequate clearance for door travel.

External Door Installation

External doors must be specified for external use with appropriate seals, finishes, and weatherproofing. Standard internal door configurations are not suitable for external applications.

Installation Guides Available

Contact Restruct Commercial Doors for product-specific installation guides and framing details.

Quality Assurance

  • Verify door closes and latches correctly from any open position
  • Check clearances are within manufacturer's tolerances
  • Confirm hardware operates smoothly and securely
  • For cavity sliders: verify smooth travel and positive latching
  • For external doors: verify seals and weatherstripping are correctly installed
  • Document installation with photos for building consent records

Maintenance Requirements

In accordance with NZ Building Code (Clause B2 Durability) and manufacturer specifications.

Maintenance Schedule

Inspection Item Frequency Requirement
Visual inspection — door condition 12-Monthly Check for damage, warping, delamination, or swelling
Hardware function 12-Monthly Hinges, handles, locks, and closers operating correctly
Door closer tension (where fitted) 12-Monthly Check and adjust closing speed and latch action as needed
Seals and weatherstripping (external doors) 12-Monthly Inspect seals for wear, damage, or loss of contact. Replace as needed
Cavity slider tracks and guides 12-Monthly Clean tracks, check rollers, verify smooth operation
Bi-fold and face slider hardware 12-Monthly Check pivot points, tracks, rollers, and alignment
Surface finish condition 12-Monthly Check for scratches, chips, or finish deterioration. Clean and repair as needed
Frame fixings and alignment 12-Monthly Frame securely fixed, plumb, and level

Cleaning

  • Clean door surfaces with mild detergent and soft cloth
  • Do not use abrasive cleaners, scouring pads, or harsh chemicals
  • Wipe dry after cleaning to prevent moisture damage

Maintenance Records

All inspections and maintenance activities must be recorded. Records should include:

  • Date of inspection
  • Inspector name
  • Findings for each inspection point
  • Details of any defects identified
  • Corrective actions taken
  • Date of next scheduled inspection

Defects Must Be Rectified Promptly

Replace worn hardware promptly. Damaged or warped door leaves should be assessed and replaced if they no longer operate correctly or meet clearance requirements.


Documentation & Resources

Download comprehensive documentation to support specification, installation, and maintenance of this product:

Installation Guides

https://restructcommercialdoors.co.nz/installation-guides/

Test Reports & Certifications

https://restructcommercialdoors.co.nz/technical-queries-evidence-requests/

Information Sheets

https://restructcommercialdoors.co.nz/information-sheets/

Need More Information? Contact our technical team for additional documentation, custom specifications, or project-specific support.


Warnings & Limitations

Critical Information — Read and understand all warnings before specifying, installing, or maintaining this product.

Performance Limitations

  • Not Fire Rated: These door systems are not fire rated. Do not use where fire resistance is required. See the RCD Fire & Smoke Door Systems BPIR disclosure page for fire-rated products.
  • Not Acoustic Rated: These door systems are not acoustic rated. Do not use where STC/Rw performance is required. See the RCD Acoustic Door Systems BPIR disclosure page for acoustic-rated products.
Critical Warning: Specifying a general purpose door where fire or acoustic performance is required is a Building Code compliance failure. Always verify the project specification requirements before selecting this product line.

Use Limitations

  • External Doors: External doors must be specifically specified for external use with appropriate seals, finishes, and weatherproofing. Standard internal configurations are not suitable for exterior installation.
  • Cavity Sliders: Require adequate wall cavity depth for the door leaf and track system. Verify cavity dimensions before specifying.
  • Do Not Modify: Any modification to the door leaf or frame may void the warranty. Do not cut, plane, drill, or alter any component without consulting the manufacturer.

Installation Warnings

  • Competent Installation Required: Doors must be installed by competent personnel with knowledge of commercial door assembly requirements.
  • Frame Fixing: Frame must be plumb, level, and securely fixed to the wall structure. Inadequate fixing leads to operational issues and premature wear.
  • Clearances: Door-to-frame clearances must be within manufacturer's specified tolerances for correct operation.

Maintenance Warnings

  • Regular Inspection Required: Annual inspection is required to maintain door performance and warranty validity.
  • No Abrasive Cleaners: Do not use abrasive cleaners on door surfaces. Use mild detergent only.
  • Hardware Replacement: Replace worn hardware promptly to prevent damage to the door leaf and frame.

Product Bans & Use Restrictions

  • No Current Product Bans: This product line is not subject to any current product bans or recalls in New Zealand.
  • Prohibited Use — Fire/Acoustic Applications: General purpose doors must not be used where fire resistance or acoustic performance is required by the building design or Building Code.

Section 26 Statement

As at 2026-03-08, the RCD General Purpose Door Systems product line is not subject to any warning or ban under Section 26 of the Building Act 2004.

Any future warnings or bans affecting this product will be immediately reflected on this disclosure page and noted on the BPIR Hub.

Regulatory Compliance

  • Building Consent: Installation may require building consent depending on the scope of work. Check with your local Building Consent Authority.

Liability Disclaimer

Restruct Commercial Doors is not liable for performance failures resulting from incorrect installation, unauthorised modifications, inadequate maintenance, or use outside specified parameters. Product warranty is only valid when installed and maintained in accordance with manufacturer specifications and relevant standards.


Document Control

Element Value
Version v1.0.0
Last Updated 2026-03-08
Change Summary Initial publication

This disclosure page is reviewed regularly and updated when product information, testing, or compliance evidence changes. Version history available on request.